SCHULZ ROTARY SCREW SRP 4008 DYNAMIC -7.5 HP 28 CFM

SCHULZ ROTARY SCREW SRP 4008 DYNAMIC -7.5 HP 28 CFM

$4,800.00$4,910.00

Clear

Technical Features

Model SRP 4008 DYNAMIC SRP 4010 DYNAMIC SRP 4015 DYNAMIC SRP 4020E DYNAMIC SRP 4025E DYNAMIC SRP 4030E DYNAMIC SRP 4040E DYNAMIC SRP 4050E DYNAMIC
Free Air @125 PSI (CFM) 25 35 51 74 92 117 150 207
Voltage (V) 230 208-230/460 208-230/460 208-230/460 208-230/460 208-230/460 208-230/460 208-230/460
Noise Level (dbA) 69 69 69 68 69 70 76 76
Tank Size (gal) 60 120 120 120 120 120 120 -
Discharge Connection (in) 1/2" 3/4" 3/4" 1" 1" 1" 1" 1 1/2"
Motor Power (hp) 7.5 10 15 20 25 30 40 50
Maximum Operating Pressure (PSI) 125 125 125 125 125 125 125 125
Code 970.3980-0 970.3902-0 970.3455-0 970.3903-0 970.3904-0 970.3907-0 970.3977-0

SRP 4008 DYNAMIC

28CFM

61 GALLON TANK

EXTREME LOW DBA

FULLY COMPUTERIZED

2 YEAR WARRANTY AIR END

1 YEAR WARRANTY EVERYTHING ELSE

5 YEAR WARRANTY AVAILABLE– CALL FOR MORE INFORMATION

 

  • TEFC, IP55, degree of protection electric motors;
  • Automatic starters with phase and sequence failure detection;
  • Lubricated air-end;
  • Low maintenance costs;
  • Low oil consumption;
  • Coolers are on the top of the machine, improves heat recovery at customer’s facilities;
  • Modern design products;
  • High efficiency electric motors;
  • Thermostatic valve for working temperature control;
  • 24V Command panel.
  • Operational Settings
    • Operation method – load/unload
    • Remote/local
    • Auto restart
    • Maintenance time to air filter, oil filter and air/oil separator, oil and main motor grease
    • Pressure and temperature units
    • Starts per hour

    Error Messages

    • Main motor and fan motor overloaded
    • Phase fault or incorrect sequence
    • Emergency
    • High pressure
    • High temperature
    • Pressure and temperature sensor

    Advantages

    Low noise level

    • Low Speed
    • Foam coated steel cabinet for noise reduction

    Low discharge temperature

    • Oversized cooling system
    • Longer oil and oil separator life time
    • Compressor prepared to handle higher ambient temperatures
    • Discharge temperature around 10°C above the ambient.

    Low maintenance

    • Synthetic oil
    • Robust belts
    • Oversized separator elements – low ppm and longer life time
    • Oversized separator elements – low ppm and longer life
    • Easy access to components for quick and simple maintenance

    Safety

    • Belt guard
    • 24 V command panel
    • Fault and sequence phase relay
    • High temperature protection