SCHULZ ROTARY SCREW SRP 4050 DYNAMIC- 50 HP -207 CFM

SKU: N/A.

SCHULZ ROTARY SCREW SRP 4050 DYNAMIC- 50 HP -207 CFM

$13,499.00$13,609.00

Clear

Technical Features

Model SRP 4008 DYNAMIC SRP 4010 DYNAMIC SRP 4015 DYNAMIC SRP 4020E DYNAMIC SRP 4025E DYNAMIC SRP 4030E DYNAMIC SRP 4040E DYNAMIC SRP 4050E DYNAMIC
Free Air @125 PSI (CFM) 25 35 51 74 92 117 150 207
Voltage (V) 230 208-230/460 208-230/460 208-230/460 208-230/460 208-230/460 208-230/460 208-230/460
Noise Level (dbA) 69 69 69 68 69 70 76 76
Tank Size (gal) 60 120 120 120 120 120 120 -
Discharge Connection (in) 1/2" 3/4" 3/4" 1" 1" 1" 1" 1 1/2"
Motor Power (hp) 7.5 10 15 20 25 30 40 50
Maximum Operating Pressure (PSI) 125 125 125 125 125 125 125 125
Code 970.3980-0 970.3902-0 970.3455-0 970.3903-0 970.3904-0 970.3907-0 970.3977-0

SRP 4050 DYNAMIC

207 CFM

EXTREME LOW DBA

FULLY COMPUTERIZED

2 YEAR WARRANTY AIR END
1 YEAR WARRANTY EVERYTHING ELSE
5 YEAR WARRANTY AVAILABLE– CALL FOR MORE INFORMATION

 

  • TEFC, IP55, degree of protection electric motors;
  • Automatic starters with phase and sequence failure detection;
  • Lubricated air-end;
  • Low maintenance costs;
  • Low oil consumption;
  • Coolers are on the top of the machine, improves heat recovery at customer’s facilities;
  • Modern design products;
  • High efficiency electric motors;
  • Thermostatic valve for working temperature control;
  • 24V Command panel.

Operational Settings

  • Operation method – load/unload
  • Remote/local
  • Auto restart
  • Maintenance time to air filter, oil filter and air/oil separator, oil and main motor grease
  • Pressure and temperature units
  • Starts per hour

Error Messages

  • Main motor and fan motor overloaded
  • Phase fault or incorrect sequence
  • Emergency
  • High pressure
  • High temperature
  • Pressure and temperature sensor

Advantages

Low noise level

  • Low Speed
  • Foam coated steel cabinet for noise reduction

Low discharge temperature

  • Oversized cooling system
  • Longer oil and oil separator life time
  • Compressor prepared to handle higher ambient temperatures
  • Discharge temperature around 10°C above the ambient.

Low maintenance

  • Synthetic oil
  • Robust belts
  • Oversized separator elements – low ppm and longer life time
  • Oversized separator elements – low ppm and longer life
  • Easy access to components for quick and simple maintenance

Safety

  • Belt guard
  • 24 V command panel
  • Fault and sequence phase relay